SPECIFICATIONS | ||
CONSTANT VOLTAGE OPERATION |
Regulation | Line regulation < 0.01% + 3mV |
Load regulation < 0.01% + 5mV ( < 10A) | ||
< 0.02% + 5mV (rating > 10A) | ||
Ripple & Noise | < 2mVrms 5Hz ~ 1MHz | |
Recovery Time | < 100µS (50% Load change, Minimum load 0.5A) | |
Output Range | 0 to rating voltage continuously adjustable | |
| ||
CONSTANT CURRENT OPERATION |
Regulation | Line regulation
< 0.2% + 3mA Load regulation < 0.2% + 3mA |
Ripple Current | <
5mArms(<20A), <
20mArms(<50A), < 100mArms(<100A) | |
Output Range | 0 to rating amperes continuously adjustable | |
| ||
METER | Digital | 3 1/2 digits
0.5" LED display Accuracy + (0.5% of rdg + 2 digits) |
| ||
INSULATION | Chassis and Terminal | 100M£[ or above ( DC 1000V ) |
Chassis and AC Cord | 100M£[ or above ( DC 1000V ) | |
| ||
POWER SOURCE | AC 120V+10%, 50/60Hz (AC 220V, or 240V order made) | |
| ||
ACCESSORIES | Instruction manual x 1, Test lead GTL-105 x 1(<3A) or GTL-104 x 1(<10A) or Not Available >10A or 600V | |
| ||
DIMENSIONS | 430(W) x 178(H) x 572(D) mm |
SELECTION GUIDE |
¡@ | Model | Output Volts (V) | Output Amps (A) |
Digital |
GPR-0875HD | 0 ~ 8 | 0 ~ 75 |
GPR-1850HD | 0 ~ 18 | 0 ~ 50 | |
GPR-3520HD | 0 ~ 35 | 0 ~ 20 | |
GPR-6015HD | 0 ~ 60 | 0 ~ 15 | |
GPR-7510HD | 0 ~ 75 | 0 ~ 10 | |
GPR-16H50D | 0 ~ 160 | 0 ~ 5 | |
GPR-25H30D | 0 ~ 250 | 0 ~ 3 | |
GPR-35H20D | 0 ~ 350 | 0 ~ 2 | |
GPR-50H15D | 0 ~ 500 | 0 ~ 1.5 | |
GPR-60H15D | 0 ~ 600 | 0 ~ 1.5 | |
GPR-100H05D | 0 ~ 1000 | 0 ~ 0.5 | |
NOTE¡GWelcome special order from 8 volts to 1000 volts and 0.5Amps to
75Amps under 1kVA
available. |