SPECIFICATIONS | ||
CONSTANT VOLTAGE OPERATION |
Regulation | Line regulation < 0.01% + 3mV |
Load regulation < 0.01% + 5mV ( < 10A) | ||
< 0.02% + 5mV ( > 10A) | ||
Ripple & Noise | < 1mVrms 5Hz ~ 1MHz | |
Recovery Time | < 100µS (50% Load change, Minimum load 0.5A) | |
Output Range | 0 to rating voltage continuously adjustable | |
| ||
CONSTANT CURRENT OPERATION |
Regulation | Line
regulation < 0.2% + 3mA Load regulation < 0.2% + 3mA |
Ripple Current | < 5mArms(<20A), < 20mArms(<50A) | |
Output Range | 0 to rating amperes continuously adjustable | |
| ||
METER | Digital | 3 1/2
digits 0.5" LED display Accuracy + (0.5% of rdg + 2 digits) |
| ||
INSULATION | Chassis and Terminal | 100M£[ or above ( DC 1000V ) |
Chassis and AC Cord | 100M£[ or above ( DC 1000V ) | |
| ||
POWER SOURCE | AC 100V/120V/220V/240V+10%, 50/60Hz | |
| ||
ACCESSORIES | Instruction manual x 1, Power cord x 1 Test lead GTL-105 x 1(<3A) or GTL-104 x 1(<10A) or Not Available >10A | |
| ||
DIMENSIONS | 255(W) x 145(H) x 420(D) mm |
SELECTION GUIDE |
¡@ | Model | Output Volts (V) | Output Amps (A) |
Digital |
GPR-0830HD | 0 ~ 8 | 0 ~ 30 |
GPR-1820HD | 0 ~ 18 | 0 ~ 20 | |
GPR-3510HD | 0 ~ 35 | 0 ~ 10 | |
GPR-6060D | 0 ~ 60 | 0 ~ 6 | |
GPR-7550H | 0 ~ 75 | 0 ~ 5 | |
GPR-11H30D | 0 ~ 110 | 0 ~ 3 | |
GPR-30H10D | 0 ~ 300 | 0 ~ 1 | |
CE APPROVED¡GGPR-1820HD, GPR-3510HD, GPR-7550D, GPR-11H30D |