MODEL : GPI-625 / GHT-106R

Withstanding Voltage/Insulation Tester

 
SPECIFICATIONS
AC HI-POT Voltage 0 ~ 2.5kV, 0 ~ 5kV 2 ranges
AC Line waveform
Voltage Regulation 20%
Max. Current 100mA

Reference Value Setting 0.5, 1, 2, 4, 8, 10, 100mA 7 ranges, combination of from 0.5 ~ 25.5mA ranges
Low Reference From 0 to one-half of reference value continuously variable

Meter 2.5kV, 5kV two ranges, ±3% of full scale

Current Monitor Meter ±5% of full scale

Insulation Resistance DC Voltage 500V/1000V
Resistance Range 1 ~ 2000M£[
Resistance Accuracy 5% ~ 10% depends on range

Judgment Description Window comparator system
Accuracy ±10% ~ ±20% depends on range

Timer 0.5S ~ 10MIN

General Type of Tests AUTO W-I, AUTO I-W, MANUAL-W, MANUAL-I
Remote Control Test, Reset and Timer On-Off control
Output Signal Test ON, GOOD, NG, and Read signal (The rating of the contact signal are 110VAC 1A or 30VDC 1A)
AC Outlet Use only Buzzer and warning light, the output voltage depend on the line voltage and the current is 1A
Test Mode Double action, good hold, momentary, NG alarm

Power Source AC 120V±10%, 50/60Hz (AC 220V/240V order made)

Accessories GHT-105 x 1,
Instruction manual x 1,
Power cord x 1 (GHT-106R for option)